Skip Navigation


Mathematical Medicine and Biology Advance Access originally published online on October 17, 2007
Mathematical Medicine and Biology 2007 24(4):347-377; doi:10.1093/imammb/dqm004
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
24/4/347    most recent
dqm004v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Heryudono, A.
Right arrow Articles by King-Smith, P. E.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Heryudono, A.
Right arrow Articles by King-Smith, P. E.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The author 2007. Published by Oxford University Press on behalf of the Institute of Mathematics and its Applications. All rights reserved.

Single-equation models for the tear film in a blink cycle: realistic lid motion

A. Heryudono, R. J. Braun{dagger}, T. A. Driscoll, K. L. Maki and L. P. Cook

Department of Mathematical Sciences, University of Delaware, Newark, DE 19711, USA

P. E. King-Smith

College of Optometry, The Ohio State University, Columbus, OH, USA

{dagger} Email: braun{at}math.udel.edu

Received on March 16, 2007. Revised on July 18, 2007. Accepted on July 19, 2007.

We consider model problems for the tear film over multiple blink cycles that utilize a single equation for the tear film; the single non-linear partial differential equation that governs the film thickness arises from lubrication theory. The two models that we consider arise from considering the absence of naturally occurring surfactant and the case when the surfactant is strongly affecting the surface tension. The film is considered on a time-varying domain length with specified film thickness and volume flux at each end; only one end of the domain is moving, which is analogous to the upper eyelid moving with each blink. Realistic lid motion from observed blinks is included in the model with end fluxes specified to more closely match the blink cycle than those previously reported. Numerical computations show quantitative agreement with in vivo tear film thickness measurements under partial blink conditions. A transition between periodic and non-periodic solutions has been estimated as a function of closure fraction and this may be a criterion for what is effectively a full blink according to fluid dynamics.

Keywords: tear film; blink cycle; partial blinks; lubrication theory; interferometry


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.